7
III. TECHNICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
PRIMARY POWER....................................
(AC) 220 VAC 50/60 Cycles
ELECTRICAL STANDARDS.....................
8VSB ATSC Transmission
ATSC: A/53, A54, A64, SMPTE-310M
SIGNAL PERFORMANCE...........................
IMD Shoulders and MER/SNR
Upper Typical -55db (FCC STDR)
Lower Typical -55dB (FCC STDR)
MER/SNR Typical -37Db
CREST FACTOR LIMITING .......................
2-12.5db Adjustable
OPERATING FREQUENCY........................
470-810 MHz*
OUTPUT POWER LEVEL...........................
1.6KW - 2.3KW Average Digital Power
INPUT TRANSPORT STREAM..................
ASI OR SMPTE-310M
WEB PAGE VIA ETHERNET......................
Remote Controled Features Are Included
(REMOTE OR LOCAL)...............................
Linear And Non-Linear Adaptive Correction
Transport Stream Selection
Output Level Adjustment
Mute/Un-Mute Control
Three (3) Level Password Protection
Up To 12 Alarm Signals
Up To 12 Analog Monitoring Ports
ALC And Power Set Features.
PROTECTION CIRCUITS............................
High Reflected Power
Over Temperature Protection
*Frequency range limited by external equipment i.e. filters and isolators. This can be modified and/or adjusted if it
becomes necessary to change channels.