User's Manual

PINEAPPLE TECHNOLOGY, INC.
DTC25U Operating and Service Manual
lll -- TRANSCODER INSTALLATION
lll -- TRANSCODER INSTALLATION
To ensure long and reliable trouble-free service from the DTC25U transcoder the following steps
for installation are recommended:
1.
MECHANICAL INSTALLATION: The DTC25U Transcoder was designed to be installed in a building
protected from the weather. The building should have a hard-surface floor such as concrete with a
moisture barrier. This barrier could be pressure-treated wood sub flooring which could be anchored
to the concrete and to the transmitter to make the installation earthquake resistant.
A
llow a minimum of three feet around the transmitter cabinet for service access. The top of the
transmitter should be clear for three feet above to allow the air to exhaust from the transmitter.
Provisions for air inlet and exhaust from the room must allow air flow with minimal obstruction.
In the event that the room temperature exceeds 35º Celsius (95º F), cooling air must be provided
so that the room temperature will not exceed 35 degrees Celsius under worse case conditions.
Notice: This equipment is HEAV
Y
and must be handled by professional movers with prope
r
equipment. Any damage caused by the installers is not covered under warranty. Check to ensur
e
that installing crews have proper insurance coverage.
2.
GROUNDING: Transmitter grounding is
V
ERY IMPORTANT and must be done correctly fo
r
safety and operational reasons. A typical installation may be done as follows
:
Use a heavy gauge wire such as 16 AWG stranded copper. The bonding between the transmitter
and the ground rods must be good quality and protected from corrosion. The ground wires should
run over the floor and be connected to the ground rods located outside the building. The wire
should not go thru the concrete floor but over and around it.
3.
AC WIRING: The DTC25U transcoder comes with a three wire 110 VAC standard plug for
connection to a 110 VAC electrical outlet. It is recommended that the electrical outlet be protected
with its own separate breaker and used only for the transcoder.
NOTICE: All wiring of this type, except for the actual connection to the AC plug, must be done
by a QUALIFIED ELECTRICIAN and must conform to LOCAL and NATIONAL wiring CODES.
Consult with your electrician to ensure that the proper breaker size is selected for the main circuit.
4.
ANTENNA CONNECTION: The transcoder is equipped with an N connector for output power to the
transmit antenna and an F connector for connection from the receive antenna.
Page 4