User's Manual
PINEAPPLE TECHNOLOGY, INC.
DTC25U Operating and Service Manual
VII -- ROUTINE MAINTENANCE
V
II --- ROUTINE MAINTENANCE
Routine Maintenance on the transmitter is very simple and straight forward. PTI recommends the following
steps to ensure long and eliable trouble-free service.
SCHEDULE: DAILY OR WEEKLY SERVICE
1. Check output power level to ensure that the meter is reading in the GREEN. If the level has changed
adjust the output level to 100% using the modulator output level adjust.
2. Check and record all meter readings in the station log.
3. Review readings and compare to history for possible variation that could indicate problems.
4. Check the air inlet filter and clean if necessary. If it looks dirty, it is dirty. Snap off the front grill an
d
wash the filter with light detergent and dry thoroughly before reinstalling. DO NOT use oils on the
filter.
5. Clear any items placed in front or in the rear of the transmitter that may restrict air flow.
NOTICE: SMALL FURRY ANIMALS LOVE THE WARMTH THE TRANSMITTER PROVIDES. ALWAYS
CHECK FOR ANY ACTIVITY BY THESE VISITORS AND SET TRAPS OR BAIT AS NECESSARY
.
SCHEDULE: MONTHLY +
A
ll the items listed above with air filter cleaning necessary.
NOTE: REPLACEMENT FILTERS ARE AVAILABLE THRU MOST ELECTRONIC DISTRIBUTERS.
LOOK FOR COMAIR ROTRON P/N: 020172
Page 16