Datasheet

www.sensirion.com Version 0.9 August 2017 11/15
6.7 Communication Data Sequences
Figure 9 Communication sequence for starting a measurement and reading measurement results.
7 Quality
7.1 Environmental Stability
The qualification of the SGP30 will be performed based on the JEDEC JESD47 qualification test method.
7.2 Material Contents
The device is fully RoHS and WEEE compliant, e.g., free of Pb, Cd, and Hg.
8 Device Package
SGP30 sensors are provided in a DFN (dual flat no leads) package with an outline of 2.45 × 2.45 × 0.9 mm
3
and a terminal
pitch of 0.8 mm. The circular sensor opening of maximally 1.6 mm diameter is centered on the top side of the package. The
sensor chip is assembled on a Ni/Pd/Au plated copper lead frame. Sensor chip and lead frame are over-molded by a black,
epoxy-based mold compound. Please note that the side walls of the package are diced and therefore the lead frame sidewall
surfaces are not plated.
8.1 Moisture Sensitivity Level
The Moisture Sensitivity Level classification of the SGP30 is MSL1, according to IPC/JEDEC J-STD-020.
8.2 Traceability
All SGP30 sensors are laser marked for simple identification and traceability. The marking on the sensor consists of the
product name and a 4-digit, alphanumeric tracking code. This code is used by Sensirion for batch-level tracking throughout
production, calibration, and testing. Detailed tracking data can be provided upon justified request. The pin-1 location is
indicated by the keyhole pattern in the light-colored central area. See Figure 10 for illustration.
Figure 10 Laser marking on SGP30. The pin-1 location is indicated by the keyhole pattern in the
light-colored central area. The bottom line contains a 4-digit alphanumeric tracking code
0
8 9
3
A X
S
GP