Data Sheet

18/40
Optical Sensor
LTR-559ALS-01
ALS_MEAS_RATE Register (0x85)
The ALS_MEAS_RATE register controls the integration time and timing of the periodic measurement of the ALS in active
mode. ALS Measurement Repeat Rate is the interval between ALS_DATA registers update. ALS Integration Time is the
measurement time for each ALS cycle.
ALS Measurement Repeat Rate must be set to be equal or larger than the ALS Integration Time. If ALS Measurement
Repeat Rate is set to be smaller than ALS Integration Time, it will automatically be reset to be equal to ALS Integration
Time by the IC internally.
Field
Bits
Default
Type
Description
Reserved
7:6
00
--
--
--
ALS
integration
time
5:3
000
RW
000
100ms (default)
001
50ms
010
200ms
011
400ms
100
150ms
101
250ms
110
300ms
111
350ms
ALS
measurement
rate
2:0
011
RW
000
50ms
001
100ms
010
200ms
011
500ms (default)
100
1000ms
101
2000ms
110
111
0x85
ALS_MEAS_RATE (default = 0x03)
B7
B6
B5
B4
B3
B2
B1
B0
Reserved
ALS Integration Time
ALS Measurement Repeat Rate