BH1745NUC
Explanation of Software Reset Command
All registers are reset and BH1745NUC becomes power down by Software reset command.
Explanation of Accessing MODE_CONTROL
If master Writes to MODE_CONTROL1(41h), MODE_CONTROL2(42h) and MODE_CONTROL3(44h) register,
RGBC measurement currently in progress is interrupted immediately and re-started from the beginning,
and VALID register returns to ‘L’. When the re-started measurement is finished, VALID register turns to ‘H’.
Power on Sequence
Please note the below behavior when application design.
1) Power on time: t1
"t1" should be more than 2ms. The IC becomes active state after 2ms by which VCC voltage goes beyond 2.0V from
less than 0.4V.
2) Power off time: t2
"t2" should be more than 1ms. The period that VCC is less than 0.4V should be more than 1ms before power supply.
* "active state" means the state that the IC operates correctly.
When power supply, INT terminal is hi-impedance state.
Once VCC goes below 2.0V, power supply sequence should follow below sequence.
0.4V
VCC
2.0V
active
Undefined behavior
t1
BH1745NUC
Undefined behavior
t2
active
t1