Owner manual
4.4 Description of the units
4 Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
4-20
The input and display field is used to
 Display the active protected field mode
See chapter 8, "Operation"
 Enter the overrun
See chapter 7, "Commissioning"
 Menu Selection
 Display the adjustment image during initial commissioning
See chapter 7, "Commissioning"
 Display the adjustment image during a tool change
See chapter 7, "Commissioning"
 Display of error messages and system data
See Chapter 9, "Diagnostics and Troubleshooting"
4.4.4 Communication with the safety system
Communication with the safety system4-Funktion_Kommunikation_Allg
Communication between the PSENvip and safety system is required if 
you use tools that cannot be safeguarded in compliance with the stand-
ards (see section entitled "Tool shapes", under "Safety"). This is the 
case with tool classes 2 and 3. User programs that do not support com-
munication with the PSENvip can be used if you only intend to safeguard 
tools of tool class 1. This is the case with older versions of the PSENvip, 
for example.
Communication between the PSENvip and the PLC safety system is 
conducted via digital inputs and outputs. Some inputs and outputs on 
the PSENvip have another function compared to normal mode.
Communication only occurs in the system status TEST. This status is 
adopted
 After power-up. 
 After a tool change. 
 After a 0/1 pulse edge at the input System-Init. 
 Periodically every 2 minutes.
Funktion_Kommunikation_P_Variante