Owner manual
12.1 Check list
12 Attachment
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
12-2
Date: ………………………………………… 
Signature: ………………………………………………………………
4 Visual inspection
Make sure that there are no objects in the protected 
space between the transmitter and receiver.
Make sure that there are no transparent materials 
between the transmitter and receiver (e.g. glass 
panel).
Are all the mechanical connections to the
PSENvip attached correctly?
Cables are undamaged?
5 Check commissioning
Has the system been commissioned correctly in ac-
cordance with the documentation?
6 Check the circuitry of the programmable safety 
and control system
Have the outputs that have been defined as OSSDs 
been incorporated in accordance with the required 
category?
Are the switching elements that are connected to 
the outputs (e.g. valves, contactors) monitored via 
feedback loops?
Does the wiring of the inputs and outputs match the 
circuit diagram?
7 Check the effectiveness of the PSENvip during 
the hazardous movement
Is the PSENvip effective throughout the whole of the 
hazardous movement of the plant/machine?
Is the safety function tested in accordance with the 
instructions specified in this documentation?
8 Check protected field modes
Do the protected field modes operate in accordance 
with the setting of the operating mode selector 
switch?
No. Action OK Not 
OK
Remarks