Manual
OPERATING MANUAL PSEN op4F/H-A series
1003067-EN-02
79
Response time of
Master AIC OFF
(ms)
Tmaster
Response time of
Slave AIC OFF
(ms)
Tslave
Response time of
Master AIC ON
(ms)
Tmaster AIC
Response time of
Slave AIC ON
(ms)
Tslave AIC
PSEN op4H-A-30-030/1
11.9
11.9
14.6
15
PSEN op4H-A-30-045/1
12.8
12.8
16.8
17
PSEN op4H-A-30-060/1
13.7
13.7
19.1
19
PSEN op4H-A-30-075/1
14.5
14.5
21.3
21
PSEN op4H-A-30-090/1
15.4 15.4 23.6 24
PSEN op4H-A-30-105/1
16.3 16.3 25.8 26
PSEN op4H-A-30-120/1
17.2
17.2
28.1
28
PSEN op4H-A-30-135/1
18.0
-
30.3
-
PSEN op4H-A-30-150/1
18.9
-
32.6
-
PSEN op4H-A-30-165/1
19.8
-
34.8
-
PSEN op4H-A-30-180/1
20.7
-
37.1
-