7.7.5 Muting timeout
The muting timeout describes the time for the maximum duration of the muting function; once
the timeout has elapsed, muting is ended.
Users have the option to set this time in BCM as well as ACM mode.
In BCM mode they can select the timeout to be 10 minutes long or infinite; “infinite” means
that the muting timeout may potentially never end: as long as the muting conditions are
present, the muting function will be maintained.
NOTE: This does not comply with the standard IEC 61496-1 and the user is
informed of this fact via a message
Fig. 46 – Muting timeout
Users have the option in the ACM mode set the muting timeout in increments of 1 minute
between 10 min und 1080 min. Alternatively, it can also be set to be infinite.
BCM configuration: Muting timeout
PWR
OSSD
EDM
ACM
LEVEL
10 min LED 7 ON green
Infinite LED 7 OFF
ACM configuration: Muting-Timeout
NOTE: The infinite timeout option does not comply with the standard