The resolution can be calculated using the following formula:
R = I + d
The table below specifies the values for the light curtains with regard to
the optical axis (I), the resolution (R) and the diameter of the optics (d).
Model Optical
axis
mm
(I)
No. of
optics
(n)
Resolution
mm
(R)
Ø of optics
mm
(d)
Range
m
PSEN op4B-T-2-050 500 2 515 16 3
PSEN op4B-T-3-080 400 3 415 16 3
PSEN op4B-L-2-050 500 2 515 16 3
PSEN op4B-L-3-080 400 3 415 16 3
PSEN op4B-S-2-050 500 2 515 16 25
PSEN op4B-S-3-080 400 3 415 16 25