User guide

PSEN op4B Series Operating Manual
44
6.7.3 Installing the muting sensors on PSEN opB-T models
The integrated muting function in a T-shaped configuration enables the
muting sensors to be easily installed and is suitable for applications in
which the object is moved in two directions.
For correct operation set position 2 on the DIP switch to ON.
A
1B1
PSEN
A
2B2
Connecting the muting sensors:
Contact from A1
Contact from A2
Contact from B1
Contact from B2
24 Vcc
4-pin M12 connector
PSEN receiver
Pin 2
MUTING 1
Pin 4
MUTING 2
L
V
=cons
D D
d
The distance d1 between A1 and B1 or A2 and B2 is 16.5 cm.
The distance D between A1 and A2 or B1 and B2 is 34.5 cm.
Muting sensors A and B must be operated consecutively within