6 FUNCTIONS
6.1 Selecting the operating mode via DIP switches
On the front of the receiver (RX) there is a cover flap (Fig. 22), which is
easy to open using a screwdriver and enables access to a row of DIP
switches for the following configurations:
- Muting function/muting timeout
- Feedback loop monitoring function
- Manual/automatic reset
The device will not accept configuration
changes during normal operation. A
configuration change will only take effect
once the device is reset.
Particular care should therefore be taken
when setting the DIP switches.
DIP-sw FUNCTION ON OFF
1 Muting timeout 10 min Infinite
2 Muting
T-shape
configuration, linear
configuration
L-shape
configuration
3
Feedback loop
monitoring
Deactivated Activated
4 Restart Automatic Manual
6.2 Standard configuration
The device is supplied with the following standard configuration:
- Muting timeout: 10 min
- Muting: In T shape configuration
- Feedback loop monitoring function: Deactivated
- Restart: Automatic
NOTE: The muting function can only be activated if muting inputs
1 and 2 and the muting lamps are connected correctly.
Detailed information on this function can be found in
chapters 6.3 and 6.4.