User guide

Operating Manual PSEN op4B Series
7
1.4 Safety information
For the proper, safe use of the safety light curtains, the following
guidelines must be followed:
It must be possible to control the machine stop electrically.
The control system must be able to stop the hazardous machine
movement immediately at any stage of the operating cycle.
The safety light curtain and its respective electrical connections
must be installed by qualified personnel, in line with the guidelines
stated in the relevant chapters.
The safety light curtain must be positioned in such a way that the
danger zone cannot be accessed without interrupting the beams
(see Chapter 2 “Installation”).
Personnel working in the danger zone must be appropriately
trained with regard to the operation of the safety light curtain.
The test/reset button must be positioned outside the danger zone
in such a way that operating personnel have a complete view of
the danger zone during all reset, test or override operations.
The feedback loop monitoring function used to monitor the external
contactors will only be active if the corresponding wire is connected
to the device.
The muting lamp that displays the activated muting function must
be visible from all sides of the work area.
To ensure the correct operation of the muting switching devices,
follow the instructions provided in the installation manual.
Before switching on the safety light curtain, make sure you comply
with the instructions regarding correct operation.