Installing the PSEN op Protective Base/1 accessories
Screw the additional plate on the floor and mount the 3 springs on
the spacers. Fix the protective column with the base plate so that
the slot holes of the bottom plate are right above the springs. Insert
the screws M10 together with the washers (PSEN op Protective
Base/1 accessories) into the slot holes and compress the 3 springs
equally when affixing the screws (Fig. 7). Align the protective
column as described in "Levelling and angular adjustment of the
plates".
The optimum working height of the springs (distance between base
plate and additional plate) is ca. 42 mm.
Fig. 7
Installing the light curtains
For the alignment of the light curtains, please refer to the operating
manual of the specific model.