User guide
PNOZ s5
Operating Manual PNOZ s5
21397-EN-09
21
Safety characteristic data
Operating
mode
EN ISO
13849-1:
2006
PL
EN ISO
13849-1:
2006
Category
EN IEC
62061
SIL CL
EN IEC
62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2006
T
M
[year]
Safety con-
tacts, instan-
taneous
PL e Cat. 4 SIL CL 3 2,31E-09 SIL 3 2,03E-06 20
Safety con-
tacts, de-
layed
PL e Cat. 4 SIL CL 3 2,34E-09 SIL 3 2,75E-05 20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Information
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
ATTENTION!
It is essential to consider the relay's service life graphs. The relay outputs'
safety-related characteristic data is only valid if the values in the service life
graphs are met.
The PFH value depends on the switching frequency and the load on the relay output. If the
service life graphs are not accessible, the stated PFH value can be used irrespective of the
switching frequency and the load, as the PFH value already considers the relay's B10d val-
ue as well as the failure rates of the other components.
Order reference
Order reference
Product type Features
Terminals
Order
no.
PNOZ s5 24 VDC
Screw terminals 750 105
PNOZ s5 C 24 VDC
Spring-loaded terminals 751 105
PNOZ s5 C
(coated ver-
sion)
24 VDC Spring-loaded terminals 751 185
PNOZ s5 48 - 240 VAC/DC
Screw terminals 750 135
PNOZ s5 C 48 - 240 VAC/DC
Spring-loaded terminals 751 135