User guide

PNOZs4
OperatingManualPNOZs4
21396EN13
14
U
B
48240VAC/DC
Example
}
Inductiveload:0,2A
}
Utilisationcategory:AC15
}
Contactservicelife:1,000,000cycles
Providedtheapplicationrequiresfewerthan1,000,000cycles,thePFHvalue(seetech
nicaldetails)canbeusedinthecalculation.
Toincreasetheservicelife,sufficientsparksuppressionmustbeprovidedonalloutput
contacts.Withcapacitiveloads,anypowersurgesthatoccurmustbenoted.Withcontact
ors,usefreewheeldiodesforsparksuppression.
Technicaldetails
Orderno.750104─751104
Seebelowformoreordernumbers
General 750104 750134 751104
Approvals
CCC,CE,EAC(Euras
ian),KOSHA,TÜV,
cULusListed
CCC,CE,EAC(Euras
ian),KOSHA,TÜV,
cULusListed
CCC,CE,EAC(Euras
ian),KOSHA,TÜV,
cULusListed