Manual

PNOZ s4
Operating Manual PNOZ s4
21396-EN-12
15
Relay outputs 750104 750134 751104 751134
Min. current 0,01 A 0,01 A 0,01 A 0,01 A
Max. power 1500 VA 1500 VA 1500 VA 1500 VA
Safety contacts,
DC1 at
24 V 24 V 24 V 24 V
Max. current 6,0 A 6,0 A 6,0 A 6,0 A
Min. current 0,01 A 0,01 A 0,01 A 0,01 A
Max. power 150 W 150 W 150 W 150 W
Utilisation category
In accordance
with the standard
EN 60947-5-1 EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Auxiliary contacts,
AC15 at
230 V 230 V 230 V 230 V
Max. current 5,0 A 3,0 A 5,0 A 3,0 A
Auxiliary contacts,
DC13 (6 cycles/
min) at
24 V 24 V 24 V 24 V
Max. current 5,0 A 4,0 A 5,0 A 4,0 A
Safety contacts,
AC15 at
230 V 230 V 230 V 230 V
Max. current 5,0 A 3,0 A 5,0 A 3,0 A
Safety contacts,
DC13 (6 cycles/
min) at
24 V 24 V 24 V 24 V
Max. current 5,0 A 4,0 A 5,0 A 4,0 A
Contact fuse protec-
tion, external safety
contacts
In accordance
with the standard
EN 60947-5-1 EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Blow-out fuse,
quick
10 A 6 A 10 A 6 A
Blow-out fuse,
slow
6 A 4 A 6 A 4 A
Circuit breaker,
24V AC/DC, char-
acteristic B/C
6 A 4 A 6 A 4 A
Contact fuse protec-
tion, external auxilia-
ry contacts
Blow-out fuse,
quick
10 A 6 A 10 A 6 A
Blow-out fuse,
slow
6 A 4 A 6 A 4 A
Circuit breaker,
24 V AC/DC,
characteristic B/C
6 A 4 A 6 A 4 A
Contact material AgCuNi + 0,2 µm
Au
AgCuNi + 0,2 µm
Au
AgCuNi + 0,2 µm
Au
AgCuNi + 0,2 µm
Au