Connection




 








 



 

 
 















 


 



  

Incremental encoder connection
Features
PNOZ s30
} Speed monitoring:
Monitoring for overspeed for the operating modes "Setup" and "Automatic", which are
selected with the switch S1.
The operating mode "Setup" is selected if the select input SEL1 is activated. Over-
speed is detected during setup at >= 50 Hz and the output Rel. 2 switches off.
The operating mode "Automatic" is selected if the select input SEL2 is activated.
Overspeed is detected during automatic mode at >= 3000 Hz and the output Rel. 2
switches off.
If a speed of 2800 Hz is exceeded, the semiconductor output Out1 switches in auto-
matic mode and a message (advance warning) is output via the PLC.
9.3.1.3
9.3.2
9.3.2.1