Owner's manual
Commissioning
Operating Manual PNOZ s30 
1001715-EN-13
45
}  Output assignment
–  Standstill: Relay output Rel. 1 and semiconductor output Out 1
–  Speed: Relay output Rel. 2 and semiconductor output Out 2
}  Reset mode
–  Rel. 1, Rel. 2 Out 1, Out 2: Automatic reset
}  Switch delay
 None
}  Max. encoder frequency
 3.5 kHz
Basic settings for the rotary encoder
Settings for basic configuration 2
Level
Indication
on the display Description Settings
1 Load Basic Parame-
ter
Encoder:
Default:
Load?
Select the default settings with 
which the basic configuration 
menu "Rotary encoder" is to be 
called:
-Load: The basic parameters are 
loaded. Switches afterwards to the 
basic menu "Rotary encoder".
The basic parameters should al-
ways be loaded when commis-
sioning for the first time.
-Edit: The basic parameters are 
not loaded, i.e. all parameters are 
retained. The basic menu parame-
ters can be changed within the 
permitted boundaries.
-ESCAPE: Exits the basic menu.
2 Encoder
Default:
TTL
differential
Select rotary encoder type -TTL differential (A, /A, B, /B)
-TTL single ended (A, B)
-HTL differential (A, /A, B, /B)
-HTL single ended (A, B)
-sin/cos 1 Vss (A, /A, B, /B)
-Hiperface (A, /A, B, /B)
2 Standstill
Rel.1 Out 1
Default:
100 Hz
Enter standstill frequency 10 mHz to 1.00 kHz
2 v max:
Rel.2 Out 2
Default:
5.00 kHz
Enter the max. permitted speed 10 mHz to 1.00 MHz
6.2.6.3