Configure Speed Monitor
The settings are made via the rotary knob, as follows:
Press the knob
} Confirm selection/setting
} Switch to menu
Rotate knob
} Select menu level
} Set the parameter/numeric value
The speed with which you turn the knob affects the sequence of the menu and numeric val-
ues:
} Slowly: Units
} Quickly: Tens
} Very quickly:
Setting the numeric value: Hundreds
When switching the menu level: Jump to ESCAPE
CAUTION!
Please note that all parameters are set to their default values on delivery.
Please check all the safety-related parameters at least, and enter the values
that correspond to your application.
Information
If no value is set or amended within 30 s of a menu action, the display re-
verts to the default display. The current setting remains unchanged.
If the master password has been entered, this time increases to 5 minutes.
Password protection
The configuration is protected through passwords. There is a master password and a cus-
tomer password.
Factory setting for both passwords: 0000
The password levels contain different authorisations:
} Master password
Display: All settings
Edit: All settings