If an output has been switched off, it cannot switch back on again until the drive has been 
run in the right direction up to the tolerance value. 
Please note:
}  Direction monitoring is always active, irrespective of whether it is used in the selected 
parameter set.
}  Direct.Right and Direct.Left are active when the PNOZ s30 is started up.
}  Direction cannot be detected if proximity switches are used.
Timing diagram for direction monitoring:
UB
Direction
s
Direct.Right
Right
Left
Standstill
Direct.Left
s
s
0 0 0 0...
0 0 0 1 2 3 4 4 ...
   1 2 3 4 4 ...
   3 2 1 0 0 ...
   3 2 1 2 1 0 0 ...
   1 2 3 2 3 4 4 ...
   1  2  3  3  ...    4 4 ...    4 4 ...    3 2 1 0 0 ...
Wrong
direction:
Wrong
direction:
s
   3 2 1 1 1 ...
   0 0 ...
   0 0 ...    1 2 3 4 4 ...
Configuration in the example:
}  Wrong direction in anti-clockwise rotation
    Max. right: 3 pulses
}  Wrong direction in clockwise rotation
    Max. left: 3 pulses
Monitoring for broken shearpins 
An additional proximity switch or an HTL signal from an additional rotary encoder can be 
connected to track Z to monitor for broken shearpins. These must both be configured as 
Z-frequency monitoring.
Hysteresis 
For each switch function F1 ... F9 (with the exception of direction and position), a hysteresis 
can be configured. This prevents the outputs on the speed monitor from bouncing if there 
are fluctuations around the response value. The hysteresis becomes effective when the 
output is switched on: 
Switch-on value = switching threshold – hysteresis 
For the lower range limit: 
Switch-on value = switching threshold + hysteresis