Datasheet
Two-hand control unit
Up to PL e of EN ISO 13849-1
P2HZ X3
1002153-EN-02-2012-12Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
-4
Terminal configuration
Klemmenbelegung
Installation
][Montage_Zweihand
The safety relay should be installed
in a control cabinet with a protec-
tion type of at least IP54.
Use the notch on the rear of the unit
to attach it to a DIN rail.
Ensure the unit is mounted securely
on a vertical DIN rail (35 mm) by us-
ing a fixing element (e.g. retaining
bracket or an end angle).
Notice
The distance of the button connected
to the two-hand relay from the nearest
danger zone must be large enough
that if one of the buttons is released,
the dangerous moment is interrupted
before the operator can reach into the
danger zone (see EN ISO 13855 "The
positioning of protective equipment in
respect of approach speeds of parts of
the human body")
Dimensions
Abmessungen
32
A2
24
19481
14
14
S11
24
S21
32
P2HZ X3
Y2
POWER
31
2313
CH.1
CH.2
A1
13
Y1
23
31
121 (4.8")
75 (2.95")
87 (3.42")
22,5
(0,89")