Datasheet

Two-hand control unit
Up to PL e of EN ISO 13849-1
P2HZ X1
1002151-EN-02-2012-05Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
-6
Number of output contacts
Safety contacts (S) instantaneous: 3
Auxiliary contacts (N/C): 1
Utilisation category in accordance with EN 60947-4-1
Safety contacts: AC1 at 240 V I
min
: 0.01 A , I
max
: 5.0 A
P
max
: 1250 VA
Safety contacts: DC1 at 24 V I
min
: 0.01 A , I
max
: 5.0 A
P
max
: 125 W
Auxiliary contacts: AC1 at 240 V I
min
: 0.01 A , I
max
: 2.0 A
P
max
: 500 VA
Auxiliary contacts: DC1 at 24 V I
min
: 0.01 A , I
max
: 2.0 A
P
max
: 50 W
Utilisation category in accordance with EN 60947-5-1
Safety contacts: AC15 at 230 V I
max
: 2.5 A
Safety contacts: DC13 at 24 V (6 cycles/min) I
max
: 1.5 A
Auxiliary contacts: AC15 at 230 V I
max
: 2.0 A
Auxiliary contacts: DC13 at 24 V (6 cycles/min) I
max
: 1.5 A
Conventional thermal current 5.0 A
Contact material AgSnO2 + 0.2µ Au
External contact fuse protection (I
K
= 1 kA) to EN 60947-5-1
Blow-out fuse, quick
Safety contacts: 6 A
Auxiliary contacts: 4 A
Blow-out fuse, slow
Safety contacts: 4 A
Auxiliary contacts: 2 A
Circuit breaker 24 VAC/DC, characteristic B/C
Safety contacts: 4 A
Auxiliary contacts: 2 A
Semiconductor outputs (short circuit proof) 24.0 V DC, 20 mA
External supply voltage 24.0 V DC
Voltage tolerance -15% / +10%
Max. overall cable resistance R
lmax
per input circuit 14 Ohm
Safety-related characteristic data
PL in accordance with EN ISO 13849-1: 2006 PL e (Cat. 4)
Category in accordance with EN 954-1 Cat. 4
SIL CL in accordance with EN IEC 62061 SIL CL 3
PFH in accordance with EN IEC 62061 3.01E-09
SIL in accordance with IEC 61511 SIL 3
PFD in accordance with IEC 61511 3.24E-06
T
M
[year] in accordance with EN ISO 13849-1: 2006 20
Times
Delay-on de-energisation (reaction time in accordance with
EN 574)
N/O contact 15 ms
N/C contact 30 ms
Recovery time 250 ms
Simultaneity, channel 1 and 2 500 ms
Environmental data
EMC EN 60947-5-1, EN 61000-6-2
Vibration to EN 60068-2-6
Frequency 10.0 - 55.0 Hz
Amplitude 0.35 mm
Climatic suitability EN 60068-2-78
Airgap creepage in accordance with EN 60947-1
Pollution degree 2
Overvoltage category III
Electrical data