Datasheet

Two-hand control unit
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
Up to PL e of EN ISO 13849-1
P2HZ X1
1002151-EN-02-2012-05
Notice
][Wichtig _PDB
This data sheet is only intended for use
during configuration. Please refer to
the operating manual for installation
and operation.
Service life graph
Lebensdauerkurve_Relais_Text vor Kurve
The service life graphs indicate the
number of cycles from which failures
due to wear must be expected. The
wear is mainly caused by the electrical
load; the mechanical load is negligible.
Lebensdauerkurve
Lebensdauerkurve_Relais_Text nach Kurve_SIR_SLR Bsp
Example
Inductive load: 0,2 A
Utilisation category: AC15
Contact service life: 4,000,000 cy-
cles
Provided the application requires few-
er than 4,000,000 cycles, the PFH val-
ue (see technical details) can be used
in the calculation.
To increase the service life, sufficient
spark suppression must be provided
on all output contacts. With capacitive
loads, any power surges that occur
must be noted. With contactors, use
freewheel diodes for spark suppres-
sion.
][Technische Daten Zweihand
Technical details
Electrical data
Supply voltage
Supply voltage U
B
AC 24 V, 42 V, 48 V, 110 V, 115 V, 120 V, 230 V, 240 V
Supply voltage U
B
DC 24 V, 26 V
Voltage tolerance -15 %/+10 %
Power consumption at U
B
AC 6.0 VA No. 774330, 774331, 774332, 774434, 774435, 774436,
774438, 774439
Power consumption at U
B
DC 2.5 W No. 774340, 774341
Frequency range AC 50 - 60 Hz
Residual ripple DC 10 % No. 774340, 774341
Voltage and current at
Input circuit DC: 24.0 V
N/O contact 30 mA
N/C contact 20 mA
Feedback loop DC: 24.0 V 45.0 mA