User Manual
PNOZ 11
Operating Manual PNOZ 11
19147-EN-05
19
Times 774080 774081 774082
Switch-on delay
With automatic start
typ. 330 ms 330 ms 330 ms
With automatic start
max. 450 ms 450 ms 450 ms
With automatic start
after power on typ. 330 ms 330 ms 330 ms
With automatic start
after power on max. 480 ms 480 ms 480 ms
With manual start typ. 335 ms 335 ms 335 ms
With manual start max. 450 ms 450 ms 450 ms
With monitored start
typ. 330 ms 330 ms 330 ms
With monitored start
max. 450 ms 450 ms 450 ms
Delay-on de-energisation
With E-STOP typ. 15 ms 15 ms 15 ms
With E-STOP max. 30 ms 30 ms 30 ms
With power failure typ. 40 ms 40 ms 40 ms
With power failure max. 60 ms 60 ms 60 ms
Recovery time at max.
switching frequency 1/s
After E-STOP 50 ms 50 ms 50 ms
After power failure 100 ms 100 ms 100 ms
Min. start pulse duration
with a monitored start 30 ms 30 ms 30 ms
Supply interruption before
de-energisation 10 ms 10 ms 10 ms
Simultaneity, channel 1
and 2 max.
∞ ∞ ∞
Environmental data 774080 774081 774082
Climatic suitability EN 60068-2-78 EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during op-
eration Not permitted Not permitted Not permitted
EMC EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
Vibration
In accordance with the
standard EN 60068-2-6 EN 60068-2-6 EN 60068-2-6
Frequency 10 - 55 Hz 10 - 55 Hz 10 - 55 Hz
Amplitude 0,35 mm 0,35 mm 0,35 mm