User Manual
PNOZ 11
Operating Manual PNOZ 11
19147-EN-05
12
Start circuit
E-STOP wiring (single-channel,
dual-channel)
Safety gate (single-channel) Safety gate (dual-channel)
Automatic start
Automatic start with start-up test
Simultaneity S1 and S2: 120ms
Manual start
S33
S34
S3
S33
S34
S3
Monitored start
S33
S34
S3
S37
S33
S34
S3
S37
NOTICE
In the event of an automatic start or manual start with bridged start contact
(fault):
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Feedback loop
without feedback loop monitor-
ing with feedback loop monitoring
Link or contacts from external
contactors