Datasheet

PNOZmulti 2 products
Fieldbus modules
PNOZ m ES Profinet
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
885
Assigning the inputs/outputs in the PNOZmulti Configurator to the
PROFINET inputs/outputs
Virtual inputs and outputs can be requested or set directly via the following objects. Each
element can be selected individually in the master control system, e.g. virtual inputs i0-31.
The data width is also established this way.
Input data
The Master writes to the virtual inputs of the PNOZmulti 2.
Description Input data from PNOZmulti 2
Virtual inputs i0 – i31 4 Input Bytes
Virtual inputs i32 – i63 4 Input Bytes
Virtual inputs i64 – i95 4 Input Bytes
Virtual inputs i96 – i127 4 Input Bytes
Output data
The Master reads the virtual outputs of the PNOZmulti 2.
Description Output data from PNOZmulti 2
Virtual outputs o0 – o31 4 Output Bytes
Virtual outputs o32 – o63 4 Output Bytes
Virtual outputs o64 – o95 4 Output Bytes
Virtual outputs o96 – o127 4 Output Bytes
Block diagram
Base unit
PROFINET
24V 0V
24V 0V FE