Datasheet

PNOZmulti 2 products
Fieldbus modules
PNOZ m ES CANopen
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
846
Setting the transmission rate
1
2
3
4
9
8
7
6
0
5
DR
} On the upper rotary switch DR, use a small screwdriver to set the transmission rate (in
the example, "3" corresponds to 50 kBit/s).
Switch setting 0 1 2 3 4 5 6 7 8 9
Transmission rate - 10
kBit/s
20
kBit/s
50
kBit/s
125
kBit/s
250
kBit/s
500
kBit/s
800
kBit/s
1
MBit/s
-
Setting the station address
The station address of the expansion module PNOZ m ES CANopen is set between 0 ... 99
(decimal) via two rotary switches x1 and x10.
1
2
3
4
9
8
7
6
0
5
x10
} On the middle rotary switch x10, use a small screwdriver to set the tens digit for the ad-
dress (“3” in the example).