Datasheet

PNOZmulti 2 products
Fieldbus modules
PNOZ m ES CANopen
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
842
Front view
Legend
LED
- Power
- Run
- Error
Rotary switch
- DR = Transmission rate
- X10 = Tens digit for the station address
- X1 = Units digit for the station address
X1: CANopen interface (male 9-pin D-Sub connector)
X4: 0 V, 24 V:
Supply connections
Functional earth
Function description
Operation
The virtual inputs and outputs that are to be transferred via CANopen are selected and con-
figured in the PNOZmulti Configurator. The base unit and the expansion module PNOZ m
ES CANopen are connected via a jumper. The station address and the transmission rate
are set using rotary switches. After the supply voltage is switched on or the control system
PNOZmulti2 is reset, the expansion module PNOZ m ES CANopen is configured and star-
ted automatically.
LEDs indicate the status of the expansion module on CANopen.
The configuration is described in detail in the PNOZmulti Configurator's online help.