Datasheet

PNOZmulti 2 products
Fieldbus modules
PNOZ m ES Profibus
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
832
Data access
The data is structured as follows:
} Virtual data
Input area PNOZ m ES Profibus
The values for the inputs are set in the Master as an output and transferred to the
PNOZmulti 2.
Output area PNOZ m ES Profibus
The outputs are configured in the PNOZmulti Configurator and transferred to the
Master.
} Status of LEDs:
Bits 0 … 4: Status of LEDs on the PNOZmulti 2
Bit 0: OFAULT
Bit 1: IFAULT
Bit 2: FAULT
Bit 3: DIAG
Bit 4: RUN
} Data exchange is displayed in Bit 5.
} Polling the payload data: 2 Bytes with the table number and segment number are sent
by the Master for access to the payload data table (15 Bytes are returned to the Mas-
ter).
Detailed information on data exchange (tables, segments) is available in the document
"Communication Interfaces" in the section entitled "Fieldbus modules".
Assigning the inputs/outputs in the PNOZmulti Configurator to the
PROFIBUS-DP inputs/outputs
Virtual inputs and outputs can be requested or set directly via the following objects. Each
element can be selected individually in the master control system, e.g. virtual inputs i0-31.
The data width is also established this way.