Datasheet

PNOZmulti 2 products
Motion monitoring modules
PNOZ m EF 2MM
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
771
Please note:
This monitoring function cannot be used in conjunction with 2 proximity switches because
position detection is not possible.
Tol
v
t
SDI
P
Safe operating stop monitoring
The Safe operating stop monitoring function (SOS-M) monitors whether the standstill po-
sition remains within a configured tolerance window. Safe operating stop monitoring is ac-
tivated within a rising edge at the start input. It remains active until the value is outside the
tolerance band. The function can be retriggered at any time by a rising edge at the start in-
put. As a result, the current position can be used at any time as the start point for the monit-
oring function.
3 SOS-M elements can be configured per axis in the PNOZmulti Configurator.
Please note:
This monitoring function cannot be used in conjunction with 2 proximity switches because
position detection is not possible.