Datasheet
PNOZmulti products
Base units
PNOZ m0p
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
77
} Two connection terminals are available for each of the supply connections 24 V and 0 V
(semiconductor outputs), plus A1 and A2 (power supply). This means that the supply
voltage can be looped through several connections. When the supply voltage is looped,
the current at each terminal may not exceed 3A.
} Test pulse outputs must exclusively be used to test the inputs. They must not be used
to drive loads.
Do not route the test pulse lines together with actuator cables within an unprotected
multicore cable.
} Test pulse outputs are also used to supply safety mats that trigger a short circuit.
Test pulses that are used for the safety mat may not be reused for other purposes.
Connection
Supply voltage AC DC
For the safety system
(connector X7)
A1
+ 24 V DC
A2
0 V
For the semiconductor outputs
(connector X2)
Must always be present, even if
the semiconductor outputs are not
used
24 V
+ 24 V DC
0 V
0 V
Supply voltage
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts across
contacts
S1
I0
L+
S1
I1
I0
L+
L+
E-STOP
with detection of shorts across
contacts
I0
T0
S1
S1
T1
I1
T0
I0
Connection examples for the input circuit