Datasheet
PNOZmulti 2 products
Motion monitoring modules
PNOZ m EF 1MM
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
747
} A proximity switch can also be connected to track Z to monitor for broken shearpins.
Please note:
Broken shearpin monitoring only becomes active when
– The minimum speed is exceeded
and
– The tolerance for detecting feasibility errors has elapsed.
The minimum speed and tolerance depend on the ratio of the frequency on tracks AB
"f
AB
" to the frequency on track Z "f
Z
" in your configuration (see PNOZmulti Configurator
Motion Monitor Element, Calculated Ratio AB/Z).
Minimum speed:
– Calculated ratio AB/Z ≥ 1.0
f
Z
= 10 mHz or f
AB
= (f
AB
/f
Z
) x 10 mHz
– at f
AB
/f
Z
Ratio < 1.0
f
AB
= 10 mHz or f
Z
= 10 mHz/(f
AB
/f
z
)
Tolerance for detecting feasibility errors:
– at f
AB
/f
Z
Ratio ≥ 1.0
7.5 Z pulses or 7.5 x (f
AB
/f
Z
) AB pulses
– at f
AB
/f
Z
Ratio < 1.0
4.5 AB pulses or 4.5 x (f
AB
/f
Z
) Z pulses
} With Hiperface encoders, the Sin- Cos track is recorded and monitored via an adapter
(see Adapters for encoders [
749]).
} Track S can be used:
– To connect an encoder's error output.
– To monitor voltages between 0 V and 30 V for a permitted upper and lower limit.
For example, the encoder's supply voltage can be monitored.
} The maximum frequency of the used encoders must be entered for a complete config-
uration.
} Pay attention to the values in the technical details.