Datasheet

PNOZmulti 2 products
Motion monitoring modules
PNOZ m EF 1MM
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
735
Function description
Operation
The motion monitoring module PNOZ m EF 1MM can monitor one axis. The motion monit-
oring module signals the status of the monitored values to the base unit. Depending on the
implemented safety circuit, the values may be transferred from the base unit to an output
on the control system. Proximity switches or encoders are used to record the values.
The configuration of the motion monitoring module is described in detail in the PNOZmulti
Configurator's online help.
The relay conforms to the following safety criteria:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
Block diagram
X4
A12 B12 S12 GND
X12
Mini-IO
Monitoring functions
The motion monitoring module PNOZ m EF 1MM supports the following monitoring func-
tions.
Please note that the position monitoring functions SOS-M, SDI-M and SS2-M cannot be
used in conjunction with 2 proximity switches, as no position can be detected.