Datasheet

PNOZmulti 2 products
Input and output modules
PNOZ m EF 4DI4DOR
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
712
O Fault
Function description
Functions
The expansion module provides additional inputs and additional relay outputs.
The function of the inputs and outputs on the control system depends on the safety circuit
created using the PNOZmulti Configurator. A chip card is used to download the safety cir-
cuit to the base unit. The base unit has 2 microcontrollers that monitor each other. They
evaluate the input circuits on the base unit and expansion modules and switch the outputs
on the base unit and expansion modules accordingly.
The online help on the PNOZmulti Configurator contains descriptions of the operating
modes and all the functions of the PNOZmulti control system, plus connection examples.
System reaction time
Calculation of the maximum reaction time between an input switching off and a linked out-
put in the system switching off is described in the document "PNOZmulti System
Expansion [
29]".
Block diagram
O0
O1
13
23
14
24
O2
O3
33
43
34
44
Input
I1I0 I3I2
Interface
to previous
module
Interface
to next
module