Datasheet

PNOZmulti 2 products
Base units
PNOZ m B1
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
694
Display Display on device Description
History:
Project history
Project
History
Select
Info
Project information is dis-
played for one of the last 16
projects activated
Name
Date / Time
Check sum FS
Check sum DP pos x
...
History x/16
Name:
_programname_
History x/16
Date 2014-01-31
Time 08:30:59
History x/16
Checksums FS:
total AB08
Operating hours
12345
Display of project information
for a selected project
Select:
Activate project
0\
\..
_dirA_
...
1\_dirA_
\..
_file.mpnoz2_
Select project contained in
the USB memory and activ-
ate it on the base unit
} Prerequisite: Device
must be stopped
} Hold down multifunction
switch for 4 s in order to
activate the project
Reset:
Reset or update project.
Project
\..
Reset
Select
After a reset, the active pro-
ject is reloaded from the
USB memory
} Prerequisite: Device
must be stopped
} Hold down multifunction
switch for 4 s in order to
reset