Datasheet
PNOZmulti Mini products
Fieldbus modules
PNOZ mmc6p
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
626
Front view
Legend:
} X4: 0 V, 24 V:
Supply connections
} X1: CANopen interface (male 9-pin D-Sub connector)
}
: Functional earth
} LED:
– Power
– Run
– Error
Function description
Operation
The virtual inputs and outputs that are to be transferred via CANopen are selected and con-
figured in the PNOZmulti Configurator. The base unit and the expansion module PNOZ
mmc6p are connected via a jumper. The station address and the transmission rate are set
using rotary switches. After the supply voltage is switched on or the PNOZmulti control sys-
tem is reset, the expansion module PNOZ mmc6p is configured and started automatically.