Datasheet
Configurable small control systems PNOZmulti Mini
Base units
Type Order number Features Common features
PNOZ mm0p [ 497]
PNOZ mm0p-T [
497]
772 000
772 010
Base unit
From 3 … 6 safety functions
Not modular and expandable
} To connect emergency stop devices, two-hand pushbuttons, safety gate limit switches,
light beam devices, scanners, enabling switches, safety gate switches PSEN, operating
mode selector switches, muting, safety mats, sensors, for example
} Can be configured in the PNOZmulti Configurator
} Exchangeable program memory
} 20 safe inputs, up to 8 of which can be configured as outputs for standard applications
} 4 safe semiconductor outputs up to PL e, SIL CL 3
} 4 semiconductor outputs, can be configured as outputs for standard applications or as
test pulses
} Display for error messages, state of the supply voltage, state of the inputs and outputs,
status and device information. Customised texts can be displayed
} Rotary knob for menu control
} Plug-in connection terminals: either spring-loaded or screw terminals (available as ac-
cessory)
} Dimensions (H x B x T): 100 x 45 x 120 mm
PNOZ mm0.1p 772 001 Base unit
From 4 safety functions and for standard control functions
} Expansion modules PNOZsigma can be connected
} 1 link module or communication module can be connected
} 1 fieldbus module can be connected
} Decentralisation: PDP67 modules can be connected to connect sensor technology
} Expanded diagnostics PVIS
From 4 safety functions and for standard control functions
PNOZ mm0.2p 772 002 Base unit
As PNOZ mm0.1p,
with additional integrated Multi-Link interface
Please refer to the section entitled System expansion [
29] for details of the number and type of connectable expansion modules for the expandable base units.
Selection guide
Configurable small control systems PNOZmulti Mini
Base units
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
60