Base units
Type Order number Features Common features
PNOZ m0p [ 71]
PNOZ m0p ETH [
71]
773 110
773 113
Base unit
From 3 … 6 safety functions
Only 1 link module and fieldbus module each can be connected,
no other expansion modules can be used,
From 3 … 6 safety functions
} To connect emergency stop devices, two-hand pushbuttons, safety gate limit
switches, light beam devices, scanners, enabling switches, safety gate switches
PSEN, operating mode selector switches, muting, safety mats, sensors, for example
} Can be configured in the PNOZmulti Configurator
} Exchangeable program memory
} Diagnostic interface
} 1 fieldbus module can be connected
} PNOZ m1p, PNOZ m2p, PNOZ m3p: Max. 8 expansion modules can be connected
} 20 safe inputs
} Semiconductor outputs:
– 4 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3
of EN IEC 62061
– 1 output for standard applications
} Positive-guided relay outputs:
– 2 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3
of EN IEC 62061
} 4 test pulse outputs
} 1 cascading input and output;
can also be used as a standard output
} LED for fault, diagnostics, supply voltage, input and output circuits
} Plug-in connection terminals: either spring-loaded or screw terminals (available as ac-
cessory)
} Dimensions (H x B x T): 94 x 135 x 121 mm
PNOZ m1p [ 91]
PNOZ m1p ETH [
91]
PNOZ m1p coated
version [
91]
PNOZ m1p ETH coated
version [
91]
772 001 Base unit
Modular and expandable, max. 8 expansion modules and 1 fieldbus module can be connected
From 4 safety functions and automation functions
PNOZ m2p [ 113]
PNOZ m2p ETH [
113]
772 002 Base unit - specifically for press applications
Monitoring of operating modes such as set-up mode, single-stroke and automatic, safety light cur-
tains in single-break and double-break mode, rotary cam arrangement with run monitoring,
press safety valves
Modular and expandable as PNOZ m1p
PNOZ m3p [ 134]
PNOZ m3p ETH [
134]
773 125
773 126
Base unit - specifically for burner management:
Control and monitoring of furnaces, e.g. monitoring of safety sequences, combustion air pressure,
ignition, flame, external compound controller and tightness control; plus control of safety valves, igni-
tion valves, exhaust valves, ignition, external compound controller and combustion air blower
Modular and expandable as PNOZ m1p
Please refer to the section entitled System expansion [
29] for details of the number and type of connectable expansion modules for the expandable base units.
Selection guide
Configurable safety systems PNOZmulti
Base units
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
55