Datasheet

PNOZmulti Mini products
Base units
PNOZ mm0p-T
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
518
} Load the project by pressing the pushbutton. For the project to be downloaded, the
pushbutton must be held down for between 4 and 8 seconds. Release the pushbutton
while the INFO LED flashes rapidly.
If you hold the pushbutton down for too long, the process will be aborted and the project
will not be downloaded.
Load project via USB port
Procedure:
} Insert a chip card into the card slot on the base unit.
} Connect the computer containing the PNOZmulti Configurator to the base unit via the
USB port.
} Switch on the supply voltage.
} Download the project (see PNOZmulti Configurator's online help).
} Once the project has been successfully downloaded, the status of the inputs and out-
puts and the supply voltage will be shown via the LEDs. The "RUN" LED is lit.
Connection
Supply voltage AC DC
For the safety system
A1
+ 24 V DC
A2
0 V
For the semiconductor outputs
Must always be present, even if
the semiconductor outputs are not
used
24 V
+ 24 V DC
0 V
0 V
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts across
contacts
S1
IM0
L+
S1
IM1
IM0
L+
L+
E-STOP
with detection of shorts across
contacts
IM0
T0M20
S1
S1
T1M21
IM1
T0M20
IM0