Datasheet

PNOZmulti products
Fieldbus modules
PNOZ mc6p/mc6.1p
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
450
Environmental data 773712 773727 773733
Condensation during op-
eration
Not permitted Short-term Not permitted
EMC EN 61131-2 EN 61131-2 EN 61131-2
Vibration
In accordance with the
standard EN 60068-2-6 EN 60068-2-6 EN 60068-2-6
Frequency 10,0 - 150,0 Hz 10,0 - 150,0 Hz 10,0 - 150,0 Hz
Acceleration 1g 1g 1g
Corrosive gas check
SO2: Concentration
10ppm, duration
10days, passive DIN V 40046-36
H2S: Concentration
1ppm, duration
10days, passive
DIN V 40046-37
Shock stress
In accordance with the
standard EN 60068-2-27 EN 60068-2-27 EN 60068-2-27
Acceleration 15g 15g 15g
Duration 11 ms 11 ms 11 ms
Max. operating height
above sea level
2000 m 2000 m 2000 m
Airgap creepage
In accordance with the
standard EN 61131-2 EN 61131-2 EN 61131-2
Overvoltage category III III III
Pollution degree 2 2 2
Rated insulation voltage 30 V 30 V 30 V
Protection type
In accordance with the
standard EN 60529 EN 60529 EN 60529
Mounting area (e.g.
control cabinet) IP54 IP54 IP54
Housing IP20 IP20 IP20
Terminals IP20 IP20 IP20
Mechanical data 773712 773727 773733
Mounting position Horizontal on top hat
rail
Horizontal on top hat
rail
Horizontal on top hat
rail
DIN rail
Top hat rail 35 x 7,5 EN 50022 35 x 7,5 EN 50022 35 x 7,5 EN 50022
Recess width 27 mm 27 mm 27 mm
Material
Bottom PPO UL 94 V0 PPO UL 94 V0 PPO UL 94 V0
Front ABS UL 94 V0 ABS UL 94 V0 ABS UL 94 V0