Front view
Function description
Functions
The data to be transferred via INTERBUS is selected and configured in the PNOZmulti
Configurator. The base unit and PNOZ fieldbus module PNOZ mc5p are connected via a
jumper. The fieldbus module is also supplied with voltage PNOZ mc5p via this jumper. After
the supply voltage is switched on or the safety system PNOZmulti is reset, the fieldbus
module PNOZ mc5p is configured and started automatically.
Input and output data
The data is structured as follows:
} Input area
The inputs are defined in the master and transferred to the PNOZmulti. Each input has
a number, e.g. input bit 4 of byte 1 has the number i12.
} Output range
The outputs are defined in the PNOZmulti Configurator. Each output that is used is
given a number there, e.g. o0, o5... The status of output o0 is stored in bit 0 of byte 0;
the status of output o5 is stored in bit 5 of byte 0 etc.
} Output range only: Byte 3
Bits 0 … 4: Status of LEDs on the PNOZmulti
Bit 0: OFAULT
Bit 1: IFAULT