Datasheet
PNOZmulti products
Speed monitors
PNOZ ms2p TTL (Coated Version)
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
314
Monitoring for broken shearpins
If the Broken shearpin monitoring option is activated, a shearpin break is recognised if
} both signals of the incremental encoder fall below the set standstill frequency (stand-
still)
and
} the proximity switch exceeds the set standstill frequency (rotating shaft).
The recognised broken shearpin leads to safe condition (see status B2 in "Signal statuses"
table in Chapter 8 of the operating manual). If individual or multiple signals change, the sys-
tem may leave a safe state (see "Signal statuses" table).
Hazards that can arise through an automatic restart must be excluded from the user pro-
gram.
Installation
Dimensions
94 (3.70")
45
(1.77")
121 (4.76")
Commissioning
General wiring guidelines
The wiring is defined in the circuit diagram of the PNOZmulti Configurator.
Details of the input type, axis type and reset mode, plus the values for standstill, speed
monitoring and direction of rotation are also defined in the PNOZmulti Configurator.
Please note:
} Information given in the Technical details [
323] must be followed.
} Use copper wiring with a temperature stability of 75 °C.