Datasheet
Basics
System expansion
Configurable safety systems PNOZmulti
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
30
System expansion depends on the base units:
Expansion modules
Slot PNOZ m0p
(ETH)
PNOZ m1p
(ETH)
PNOZ m2p
(ETH)
PNOZ m3p
(ETH)
Number of connectable modules
Analogue input modules Left - 4 4 4
PNOZ ma1p Analogue input module
Link modules Left 4 4 4 4
PNOZ ml1p To connect 2 base
units
PNOZ ml2p To connect a base unit
to up to 4 decentralised
modules PDP67 (see
below)
Decentralised modules (connectable
to the link module PNOZ ml2p)
Left 16 16 16 16
PDP67 F 8DI
ION
IP67, 8 safe inputs
PDP67 F 8DI
ION HP
IP67, 8 safe inputs
Input modules Right - 8 8 8
PNOZ mi1p 8 safe inputs
PNOZ mi2p 8 inputs for standard
applications
Output modules Right - 6 6 6
PNOZ mo1p 4 safe semiconductor
outputs
PNOZ mo2p 2 safe relay outputs
PNOZ mo3p 2 safe 2-pole semicon-
ductor outputs
PNOZ mo4p 4 safe relay outputs
PNOZ mo5p 4 safe, diverse relay
outputs
Output modules for standard applic-
ations
Right - 8 8 8
PNOZ mc1p 16 semiconductor out-
puts for standard ap-
plications