Datasheet

PNOZmulti products
Link modules
PNOZ ml1p
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
250
Virtual inputs and outputs:
Inputs and outputs for both PNOZmulti systems are assigned in the PNOZmulti Configur-
ator. Inputs and outputs with the same number are assigned to each other, e.g. output o5
on one PNOZmulti system to input i5 on the other PNOZmulti system.
Base unit 1
Virtual outputs
o0
...
o31
Virtual inputs
i0
...
i31
Base unit 2
Virtual inputs
i0
...
i31
Virtual outputs
o0
...
o31
System reaction time
Calculation of the maximum reaction time between an input switching off and a linked out-
put in the system switching off is described in the document "PNOZmulti System
Expansion [
29]".
Block diagram
24V 24V
=
Power
=
0V 0V
Interface
to next
module
Interface
to previous
module
CA+ CA-
CB+ CB-
Shield