Datasheet
PNOZmulti products
Output modules
PNOZ mo2p
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
183
Front view
773520
Key:
} O0 – O1
Relay outputs
Function description
Functions
The expansion module provides additional relay outputs.
The function of the outputs on the safety system depends on the safety circuit created us-
ing the PNOZmulti Configurator. A chip card is used to download the safety circuit to the
base unit. The base unit has 2 microcontrollers that monitor each other. They evaluate the
input circuits on the base unit and expansion modules and switch the outputs on the base
unit and expansion modules accordingly.
The online help on the PNOZmulti Configurator contains descriptions of the operating
modes and all the functions of the PNOZmulti safety system, plus connection examples.
System reaction time
Calculation of the maximum reaction time between an input switching off and a linked out-
put in the system switching off is described in the document "PNOZmulti System
Expansion [
29]".