Function description
Functions
The function of the inputs and outputs on the control system depends on the safety circuit
created using the PNOZmulti Configurator. A chip card is used to download the safety cir-
cuit to the base unit. The base unit has 2 microcontrollers that monitor each other. They
evaluate the input circuits on the base unit and expansion modules and switch the outputs
on the base unit and expansion modules accordingly.
The LEDs on the base unit and expansion modules indicate the status of the configurable
control system PNOZmulti.
The online help on the PNOZmulti Configurator contains descriptions of the operating
modes and all the functions of the control system, plus connection examples.
Application on mechanical presses
The base unit PNOZ m2p is designed for applications on mechanical presses (see online
help for the PNOZmulti Configurator).
Functions:
} Operating modes
Set-up mode
Single stroke
Automatic
} Monitoring a mechanical rotary cam arrangement
} Run monitoring
} Monitoring of electrosensitive protective equipment (cycle mode)
} Driving and monitoring a press safety valve