Datasheet
Basics
System description
Hardware
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
10
Operation of the units
The PNOZmulti Configurator generates a project file which is downloaded to the base unit;
there it defines
} Which safety functions the inputs are to carry out, e.g. E-STOP monitoring, safety gate
monitoring
} How the inputs are connected to the outputs via logic functions
} Which output is configured (semiconductor, relay)
The units react the same, irrespective of these functions:
If the start-up condition of the specific safety function is met, there will be a high signal at
the output “Out1”. The output signal can be linked via a logic function and is then present
as the “Out2” signal at the output on the PNOZmulti unit.
Inputs
Safety functions
e.g.
E-STOP
safety gate
Logic functions
e.g.
AND
OR
delay
semiconductor
relay
Outputs
Out1
Out2