Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
860
Level Menu designation Description Settings
2 (F1 ... F9) Function
Hysteresis
Default
1 %
Enter hysteresis for the switching
functions F1 ... F9
(not effective with position and dir-
ection monitoring)
0 ... 50 %
1 Output Delay Setting for the delay effect and
delay time for the outputs
2 Delay Output
(Rel.1 ... Out 4)
Default
On 0 ms (display
only)
Setting for the delay time effect
and delay time for the respective
output
3 Delay Effect
(Rel.1 ... Out 4)
Default
On delay
Enter whether the delay time is to
be activated when switching on,
switching off, or switching on and
off.
- On
- Off
-OnOff
3 Delay Time
(Rel.1 ... Out 4)
Default
tdO: 0 ms
Select delay time for the respect-
ive output
0 ... 30.0 s
1 Output Out Logic Setting for the switching direction
of the semiconductor outputs
2 output
(Out 1 ... Out 4)
Logic
Default
N/O contact
Select the switching direction of
the semiconductor outputs Out
1 ... Out 4:
N/O contact (normally energised
mode)
N/C contact (normally de-ener-
gised mode)
- N/O contact
- N/C contact
1 Name of Configura-
tion
Default
Default
Enter name of the configuration
The name may be a max. of 8
characters in length
It is stored on the chip card
........